BB14 SeriesIntercept® Back BoxInstallation/Operation ManualC454M-C (1/98)Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.comIn North A
10 Pelco Manual C454M-C (1/98)3.1.2 Hard Ceiling MountingFor installing the back box in a hard ceiling, an optional backup plate is provided forappli
Pelco Manual C454M-C (1/98) 113.1.3 Pendant MountingThe pendant back box is designed to be suspended from a suitable length of 1-1/2”pipe threaded at
12 Pelco Manual C454M-C (1/98)3.2 WIRING INSTRUCTIONSHow your back box will be wired depends on the type of unit you have:Units with an on-board rece
Pelco Manual C454M-C (1/98) 13Table A. Video Coaxial Cable RequirementsCable Type* Maximum DistanceRG59/U 750 ft (229 m)RG6/U 1,000 ft (305 m)RG11/U
14 Pelco Manual C454M-C (1/98)Figure 3. 24 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)
Pelco Manual C454M-C (1/98) 15Figure 4. 120 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)
16 Pelco Manual C454M-C (1/98)Figure 5. 230 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)
Pelco Manual C454M-C (1/98) 173.2.2 Hard-Wire or Remote Receiver/DriverRefer to Figures 6 and 7 for wiring diagrams.Refer to Table A for the type of
18 Pelco Manual C454M-C (1/98)Figure 6. Wiring Diagram, Hard-Wire Control with HeaterNOTE: For fixed mount or dome drive with blower/heaters and wit
Pelco Manual C454M-C (1/98) 19Figure 7. Wiring Diagram, Hard-Wire Control without HeaterNOTE: For use in domes without integral receiver/driver or h
2 Pelco Manual C454M-C (1/98)CONTENTSSection Page1.0 GENERAL ...
20 Pelco Manual C454M-C (1/98)3.2.3 Heater/Blower Kit Field InstallationThe kits are shipped partially assembled, to complete assembly and to install
Pelco Manual C454M-C (1/98) 214.0 EXPLODED ASSEMBLY DIAGRAMSFigure 8. Suspended Ceiling Back Box Exploded Assembly DiagramTable C. Suspended Ceilin
22 Pelco Manual C454M-C (1/98)Item Quantity Description Part Number11Trim ring, white SB262ASSY21Back box 8141202WA31Plate, gland 8004130COMP44Receive
Pelco Manual C454M-C (1/98) 23Figure 10. Pendant Back Box Exploded Assembly DiagramTable E. Pendant Back Box Exploded Assembly Part ListItem Quantit
24 Pelco Manual C454M-C (1/98)Figure 11. Back Plate Exploded Assembly Diagram
Pelco Manual C454M-C (1/98) 25Table F. Back Plate Exploded Assembly Parts List (Figure 11)Item Quantity Description Part Number12Latch backup plate 8
26 Pelco Manual C454M-C (1/98)5.0 SPECIFICATIONSELECTRICALEnclosure Back BoxInput Voltage: 24 VAC or 120 VACPower RequirementsReceiver/Driver: 48 vA
Pelco Manual C454M-C (1/98) 27Figure 12. Suspended/Hard Ceiling Dimension DrawingsFigure 13. Pendant-Mount Dimension DrawingNOTE: VALUES IN PARENTH
28 Pelco Manual C454M-C (1/98)6.0 WARRANTY AND RETURN INFORMATIONThis equipment contains electrical or electronic components that must be recycled pr
Pelco Manual C454M-C (1/98) 3REVISION HISTORYManual # Date CommentsC454M — Original version.C454M-A 6/95 Revised to incorporate B.O.M. quantity change
4 Pelco Manual C454M-C (1/98)(This page intentionally left blank.)
Pelco Manual C454M-C (1/98) 5Please thoroughly familiarize yourself with the informationin this manual prior to installation and operation.1.0 GENERA
6 Pelco Manual C454M-C (1/98)1.2 UNPACKING INSTRUCTIONSUnpack and inspect all parts carefully.Be sure to save the shipping carton and any inserts. Th
Pelco Manual C454M-C (1/98) 72.0 DESCRIPTIONThe BB14 Series of back boxes is part of the IDS14 Intercept® Series of domes.The IDS14 Series is an inte
8 Pelco Manual C454M-C (1/98)Indoor, PendantBB14E100 Indoor, black, pendant-mount back box; smoked dome; hard-wire control. (CE, UL)BB14E101 Indoor, b
Pelco Manual C454M-C (1/98) 93.0 INSTALLATION3.1 MOUNTINGThe Intercept® Series of domes provide back box configurations for several applica-tions an